431 on a NIBE heat pump: Inverter alarm type I / high mains voltage: Phase voltage to the inverter too high for more than 1 hour (or 3 times within 3 hours) [other NIBE documents: Phase voltage to inverter too high 3 times within 3 h or continuously 1 h / Phase voltage to inverter too high, 3 times within 2 h or persistently 1 h]
Short answer
On a NIBE heat pump, 431 means: Inverter alarm type I / high mains voltage: Phase voltage to the inverter too high for more than 1 hour (or 3 times within 3 hours) [other NIBE documents: Phase voltage to inverter too high 3 times within 3 h or continuously 1 h / Phase voltage to inverter too high, 3 times within 2 h or persistently 1 h]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Inverter alarm type I / high mains voltage: Phase voltage to the inverter too high for more than 1 hour (or 3 times within 3 hours) [other NIBE documents: Phase voltage to inverter too high 3 times within 3 h or continuously 1 h / Phase voltage to inverter too high, 3 times within 2 h or persistently 1 h].
Part involved: inverter and compressor drive.
When it shows: Phase voltage to the inverter too high for more than 1 hour (or 3 times within 3 hours); Phase voltage to inverter too high 3 times within 3 h or continuously 1 h; Phase voltage to inverter too high, 3 times within 2 h or persistently 1 h; Phase voltage to inverter too high, 3 times within 3 hours or persistent for 1 hour.
Likely causes:
- F2120: High voltage in to F2120 | F2120: Disruption in supply voltage.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: no/unknown - Compressor blocked. Manual reset in menu; Compressor blocked.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains - NIBE: Compressor blocked. Manual reset in menu; Compressor blocked.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Main and group fuses and their cable connections; High voltage in to F2120; Disruption in supply voltage.
Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.
Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- TECHNICAL INFORMATION - ALARM LIST SMO 40 (TIF EN 2042-1, M12658EN) ↗ · TIF EN 2042-1 M12658EN · page 10 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026