401 on a NIBE heat pump: Unspecified fault: The slave sends a message that does not exist in the master [other NIBE documents: Initiation fault inverter / inverter not compatible / configuration file missing / charge error configuration]

Short answer

On a NIBE heat pump, 401 means: Unspecified fault: The slave sends a message that does not exist in the master [other NIBE documents: Initiation fault inverter / inverter not compatible / configuration file missing / charge error configuration]. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Unspecified fault: The slave sends a message that does not exist in the master [other NIBE documents: Initiation fault inverter / inverter not compatible / configuration file missing / charge error configuration].

Part involved: PCB / software configuration.

When it shows: The slave sends a message that does not exist in the master; Initiation fault inverter / inverter not compatible / configuration file missing / charge error configuration.

Likely causes:

  • F2120: Inverter initiation or configuration fault.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Blocks the compressor; frost protection reset.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Note the alarm and contact your installer; no homeowner action beyond resetting.

What the engineer will check

  • Check serial number/software versions, PCB type and DIP switch settings; update software or replace PCB as required. NIBE lists: Update the software in master and slave; Inverter initiation or configuration fault.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026