380 on a NIBE heat pump: Flow protect defrost: Low flow for a certain time triggers alarm to cancel defrosting

Short answer

On a NIBE heat pump, 380 means: Flow protect defrost: Low flow for a certain time triggers alarm to cancel defrosting. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow protect defrost: Low flow for a certain time triggers alarm to cancel defrosting.

Part involved: evaporator defrost.

When it shows: Low flow for a certain time triggers alarm to cancel defrosting.

Likely causes:

  • S2060: Low temperature; dirt in filters; low flow.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning

The heat pump keeps running with some functions stopped.

Resetting itself: yes - information messages reset automatically when the cause is rectified.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the outdoor unit is not blocked by leaves, snow or ice and that nothing obstructs the airflow.

What the engineer will check

  • Check system volume and flow during defrost, particle filter, circulation pump, evaporator airflow, evaporator/defrost sensors and refrigerant circuit. NIBE lists: Low temperature; dirt in filters; low flow.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice