368 on a NIBE heat pump: Sensor fault EPxx, BT3 return line sensor (listed as range 361-368): BT3 (return) not connected/defective in one of the climate systems

Short answer

On a NIBE heat pump, 368 means: Sensor fault EPxx, BT3 return line sensor (listed as range 361-368): BT3 (return) not connected/defective in one of the climate systems. The heat pump keeps running.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Sensor fault EPxx, BT3 return line sensor (listed as range 361-368): BT3 (return) not connected/defective in one of the climate systems.
  • Error MCB card: Communication to MCB card (base card AA2) missing.

Part involved: temperature/pressure sensor; PCB / accessory board communication.

When it shows: BT3 (return) not connected/defective in one of the climate systems Communication to MCB card (base card AA2) missing.

Likely causes:

  • Sensor not connected; open-circuit or defective sensor.

Is it safe?

Does the heat pump stop?No
SeverityWarning

The heat pump keeps running.

Resetting itself: yes - -.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input. NIBE lists: Sensor not connected; open-circuit or defective sensor.
  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026