SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · NIBE
353NIBE · NIBE, all models

353 on a NIBE heat pump: Uncertain sensor accuracy (BT3/BT12): Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration

Short answer

On a NIBE heat pump, 353 means: Uncertain sensor accuracy (BT3/BT12): Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Uncertain sensor accuracy (BT3/BT12): Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration.
  • Failed start, no press. diff: Pressure difference between BP9 and BP8 too low at compressor start 3 times within 30 minutes.

Part involved: temperature/pressure sensor; pressure switches/sensors, expansion valve.

When it shows: Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration Pressure difference between BP9 and BP8 too low at compressor start 3 times within 30 minutes.

Likely causes:

  • S2125: Fault in pressure sensor BP8/BP9; compressor not compressing sufficiently; compressor breakdown | F2120: Fault in pressure sensor BP8/BP9; compressor not compressing sufficiently; compressor breakdown.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: no/unknown - GP1 switches to manual speed; manual reset in menu 5.1.11.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains - NIBE: GP1 switches to manual speed; manual reset in menu 5.1.11.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Air source systems: check the outdoor unit is clear of leaves/snow/ice. Read the heating system pressure gauge and note the reading for your installer.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input.
  • Check heating medium flow, particle filter and circulation pump; check pressure switches/sensors, expansion valve, service valves and refrigerant charge (F-gas qualified). NIBE lists: Fault in pressure sensor BP8/BP9; compressor not compressing sufficiently; compressor breakdown.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); Heat pump engineer with F-gas qualification (NIBE-trained / NIBE PRO installer).

Certification: Electrical work to BS 7671 by a competent person; F-gas certification for refrigerant circuit work (plus flammable-refrigerant competence for R290/R32 models).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026