334 on a NIBE heat pump: Max. incoming temp. exceeded: Max temperature through outdoor unit exceeded: BT3 higher than 65 C in heating mode
Short answer
On a NIBE heat pump, 334 means: Max. incoming temp. exceeded: Max temperature through outdoor unit exceeded: BT3 higher than 65 C in heating mode. The heat pump keeps running with some functions stopped.
Reviewed 23 September 2026 · 2 sources
What it means
The manuals for this range word it in different ways:
- Max. incoming temp. exceeded: Max temperature through outdoor unit exceeded: BT3 higher than 65 C in heating mode.
- Failed compressor start: Compressor does not start when required, 3 times within 2 hours [other NIBE documents: Compressor temporarily ran below minimum permitted speed 3 times within 2 hours or for 1 hour].
Part involved: heating medium flow, charge pump, particle filter; inverter and compressor drive.
When it shows: Max temperature through outdoor unit exceeded: BT3 higher than 65 C in heating mode Compressor does not start when required, 3 times within 2 hours; Compressor temporarily ran below minimum permitted speed 3 times within 2 hours or for 1 hour.
Likely causes:
- Undersized heating system; incorrect heating curve; flow-related; additional heat incorrectly connected.
- S2125: Defective inverter; defective compressor | F2120: Defective inverter; defective compressor.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Warning |
The heat pump keeps running with some functions stopped.
Resetting itself: yes - Heating prioritisation blocked.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Read the heating system pressure gauge and check that radiator/underfloor thermostats are not all closed; check heating and hot water temperature settings have not been changed.
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check heating medium flow (pump speed/settings, particle filter, air in system), heating curve and hot water settings, correct sensor placement and flow/return connections. NIBE lists: Undersized heating system; incorrect heating curve; flow-related; additional heat incorrectly connected.
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Defective inverter; defective compressor.
Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); NIBE-trained heat pump engineer and/or qualified electrician.
Certification: None specific beyond competent heat pump installer; electrical work to BS 7671; Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- TECHNICAL INFORMATION - ALARM LIST SMO 40 (TIF EN 2042-1, M12658EN) ↗ · TIF EN 2042-1 M12658EN · page 17 · Reviewed 23 September 2026
- Installer manual Air/water heat pump NIBE S2125 UK 1x230V IHB EN 2525-1 (831874) ↗ · IHB EN 2525-1 · page 42 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026