328 on a NIBE heat pump: Mains disturbance: Temporary fault in inverter, 3 times within 2 hours or continuously 1 hour [other NIBE documents: Temporary fault in inverter, 3 times within 2 hours or continuously for 1 hour / Temporary inverter fault 3 times within 2 hours or continuously 1 hour]
Short answer
On a NIBE heat pump, 328 means: Mains disturbance: Temporary fault in inverter, 3 times within 2 hours or continuously 1 hour [other NIBE documents: Temporary fault in inverter, 3 times within 2 hours or continuously for 1 hour / Temporary inverter fault 3 times within 2 hours or continuously 1 hour]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Mains disturbance: Temporary fault in inverter, 3 times within 2 hours or continuously 1 hour [other NIBE documents: Temporary fault in inverter, 3 times within 2 hours or continuously for 1 hour / Temporary inverter fault 3 times within 2 hours or continuously 1 hour].
Part involved: inverter and compressor drive.
When it shows: Temporary fault in inverter, 3 times within 2 hours or continuously 1 hour; Temporary fault in inverter, 3 times within 2 hours or continuously for 1 hour; Temporary inverter fault 3 times within 2 hours or continuously 1 hour.
Likely causes:
- S2125: Disruption in supply voltage; incorrect connection in inverter terminal block X1 | F2120: Disruption in supply voltage; incorrect connection in inverter terminal block X1.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: no/unknown - Compressor blocked. Manual reset in menu.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains - NIBE: Compressor blocked. Manual reset in menu.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Disruption in supply voltage; incorrect connection in inverter terminal block X1.
Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.
Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- Installer manual Air/water heat pump NIBE S2125 UK 1x230V IHB EN 2525-1 (831874) ↗ · IHB EN 2525-1 · page 42 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026