298 on a NIBE heat pump: Preheat. failed, long run time: The inverter has tried to heat up the compressor but has failed

Short answer

On a NIBE heat pump, 298 means: Preheat. failed, long run time: The inverter has tried to heat up the compressor but has failed. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Preheat. failed, long run time: The inverter has tried to heat up the compressor but has failed.
  • Uncertain sensor accuracy: Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration.

Part involved: compressor discharge (hot gas); temperature/pressure sensor.

When it shows: The inverter has tried to heat up the compressor but has failed Heating medium sensors BT3 and BT12 differ by more than 2 K at calibration.

Likely causes:

  • S2125: Defective inverter; discharge sensor BT14 has come loose from its mount.

Is it safe?

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - not stated.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Air source systems: check the outdoor unit is clear of leaves/snow/ice. Read the heating system pressure gauge and note the reading for your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check discharge sensor BT14 mounting, refrigerant charge and circuit (F-gas qualified), airflow over evaporator and heating medium flow. NIBE lists: Defective inverter; discharge sensor BT14 has come loose from its mount.
  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input.

Who to ask for: Heat pump engineer with F-gas qualification (NIBE-trained / NIBE PRO installer); NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: F-gas certification for refrigerant circuit work (plus flammable-refrigerant competence for R290/R32 models); Electrical work to BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026