Heat pumps · Error codes · NIBE
292NIBE · NIBE, all models

292 on a NIBE heat pump: Sen flt: BT74 cool/heat sen.: Sensor BT74 on AUX input not connected/defective

Short answer

On a NIBE heat pump, 292 means: Sen flt: BT74 cool/heat sen.: Sensor BT74 on AUX input not connected/defective. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Sen flt: BT74 cool/heat sen.: Sensor BT74 on AUX input not connected/defective.
  • Low temperature water: Low temperature during cooling mode.

Part involved: temperature/pressure sensor; heating medium flow, charge pump, particle filter.

When it shows: Sensor BT74 on AUX input not connected/defective Low temperature during cooling mode.

Likely causes:

  • Open circuit or short circuit on sensor input; defective sensor.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: no/unknown - According to selected measure in menu.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Read the heating system pressure gauge and check that radiator/underfloor thermostats are not all closed; check heating and hot water temperature settings have not been changed.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input. NIBE lists: Open circuit or short circuit on sensor input; defective sensor.
  • Check heating medium flow (pump speed/settings, particle filter, air in system), heating curve and hot water settings, correct sensor placement and flow/return connections.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026