287 on a NIBE heat pump: Refrigerant sensor has to be replaced soon: Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited

Short answer

On a NIBE heat pump, 287 means: Refrigerant sensor has to be replaced soon: Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited. The manual does not say whether the heat pump stops.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Refrigerant sensor has to be replaced soon: Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited.

Part involved: refrigerant (leak) sensor BQ10.

When it shows: Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited.

Likely causes:

  • S2060: Warning appears monthly from 14.5 years until 15 years.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning

The manual does not say whether the heat pump stops.

Resetting itself: yes - information messages reset automatically when the cause is rectified.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check refrigerant sensor BQ10 and its cable; replace sensor at end of life (15 years) per NIBE instructions. Treat as R290 safety function. NIBE lists: Warning appears monthly from 14.5 years until 15 years.

Who to ask for: NIBE-trained heat pump engineer competent with R290 (A3) refrigerant systems.

Certification: Competence for flammable (A3, R290) refrigerant systems; F-gas certification if the refrigerant circuit is opened.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026