268 on a NIBE heat pump: Overcurrent, inverter A/F module (generated by heat pump): Overcurrent in inverter A/F module [other NIBE documents: Overcurrent, inverter A/F module / Overcurrent in the inverter]

Short answer

On a NIBE heat pump, 268 means: Overcurrent, inverter A/F module (generated by heat pump): Overcurrent in inverter A/F module [other NIBE documents: Overcurrent, inverter A/F module / Overcurrent in the inverter]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Overcurrent, inverter A/F module (generated by heat pump): Overcurrent in inverter A/F module [other NIBE documents: Overcurrent, inverter A/F module / Overcurrent in the inverter].
  • Low extract air temperature: Extract air temperature (BT21) in ERS (AZ30) below 0 C for 10 minutes.

Part involved: inverter and compressor drive; fans, air filters, air sensors.

When it shows: Overcurrent in inverter A/F module; Overcurrent, inverter A/F module; Overcurrent in the inverter Extract air temperature (BT21) in ERS (AZ30) below 0 C for 10 minutes.

Likely causes:

  • S2060: Sudden power failure | F2050: Sudden power failure | F2040: Sudden power failure.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.

What the engineer will check

  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Sudden power failure.
  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor.

Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician; NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales); None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.