263 on a NIBE heat pump: Inverter error - incorrect voltage (generated by heat pump): Incorrect voltage out from the inverter [other NIBE documents: Voltage from the inverter outside parameters 4 times within 30 minutes / Abnormally high current detected by the inverter]

Short answer

On a NIBE heat pump, 263 means: Inverter error - incorrect voltage (generated by heat pump): Incorrect voltage out from the inverter [other NIBE documents: Voltage from the inverter outside parameters 4 times within 30 minutes / Abnormally high current detected by the inverter]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Inverter error - incorrect voltage (generated by heat pump): Incorrect voltage out from the inverter [other NIBE documents: Voltage from the inverter outside parameters 4 times within 30 minutes / Abnormally high current detected by the inverter].
  • Compressor phase overloaded: Load monitor has prevented the compressor operating at desired power.

Part involved: inverter and compressor drive.

When it shows: Incorrect voltage out from the inverter; Voltage from the inverter outside parameters 4 times within 30 minutes; Abnormally high current detected by the inverter; Voltage from the inverter outside parameters four times within 30 minutes; Voltage from inverter outside parameters four times within 30 minutes Load monitor has prevented the compressor operating at desired power.

Likely causes:

  • S2060: Communication faults between inverter and control unit | F2050: Incoming power supply interference; service valve closed; insufficient refrigerant; compressor fault; defective inverter board | F2040: Incoming power supply interference; service valve closed; insufficient refrigerant; compressor fault; defective inverter board.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.

What the engineer will check

  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Incoming power supply interference; service valve closed; insufficient refrigerant; compressor fault; defective inverter board in F2040/AMS; Communication faults between inverter and control unit; Incoming power supply interference; service valve closed; insufficient refrigerant; compressor fault; defective inverter board.
  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor.

Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.

Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.