255 on a NIBE heat pump: Motor protection alarm, brine pump: Motor protection on the brine pump triggered
Short answer
On a NIBE heat pump, 255 means: Motor protection alarm, brine pump: Motor protection on the brine pump triggered. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 2 sources
What it means
The manuals for this range word it in different ways:
- Motor protection alarm, brine pump: Motor protection on the brine pump triggered.
- Inverter PCB fault: The power transistor emits a fault signal [other NIBE documents: Continuous deviation on power transistor for 15 minutes / Continuous error on power transistor for 15 minutes].
Part involved: inverter and compressor drive.
When it shows: Motor protection on the brine pump triggered The power transistor emits a fault signal; Continuous deviation on power transistor for 15 minutes; Continuous error on power transistor for 15 minutes.
Likely causes:
- S2060: Defective fan motor; defective inverter board QA40 (PWB2) | F2050: Defective fan motor; defective inverter board.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: yes - Current compressor blocked. Automatic reset.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor.
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Defective fan motor; defective inverter board QA40 (PWB2); Defective fan motor; defective inverter board.
Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.
Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- ALARM LIST - NIBE products with Emmy display, Version 1747-1 (updated 2017-11-23) ↗ · 1747-1 · page 8 · Reviewed 23 September 2026
- Installer manual Air/water heat pump NIBE S2060 UK 1x230V IHB EN 2623-3 (831281) ↗ · IHB EN 2623-3 · page 31 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026