252 on a NIBE heat pump: Com. error slave: Temporarily no communication with slave heat pump

Short answer

On a NIBE heat pump, 252 means: Com. error slave: Temporarily no communication with slave heat pump. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Com. error slave: Temporarily no communication with slave heat pump.
  • Power transistor too hot: Protection against damage if current too high [other NIBE documents: IPM displays FO fault output five times during 60 minutes / Overheated power transistor].

Part involved: PCB / accessory board communication; inverter and compressor drive.

When it shows: Temporarily no communication with slave heat pump Protection against damage if current too high; IPM displays FO fault output five times during 60 minutes; Overheated power transistor.

Likely causes:

  • S2060: Interference on incoming supply; service valve closed; insufficient refrigerant; compressor fault; defective inverter board QA40 (PWB2) | F2050: 15 V power supply to inverter PCB unstable.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor in slave blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.
  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Interference on incoming supply; service valve closed; insufficient refrigerant; compressor fault; defective inverter board QA40 (PWB2); 15 V power supply to inverter PCB unstable.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); NIBE-trained heat pump engineer and/or qualified electrician.

Certification: Electrical work to BS 7671 by a competent person; Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026