248NIBE · NIBE, all models

248 on a NIBE heat pump: Communication fault (display - base card): No connection between the display unit and the base card

Short answer

On a NIBE heat pump, 248 means: Communication fault (display - base card): No connection between the display unit and the base card. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Communication fault (display - base card): No connection between the display unit and the base card.
  • Refrigerant sensor has to be replaced soon: Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited.

Part involved: PCB / accessory board communication; refrigerant (leak) sensor BQ10.

When it shows: No connection between the display unit and the base card Refrigerant sensor BQ10 must be replaced soon; if not replaced within the stated days operation will be limited.

Likely causes:

  • S2060: Warning appears monthly from 14.5 years until 15 years.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor and charging pump stopped.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.
  • Check refrigerant sensor BQ10 and its cable; replace sensor at end of life (15 years) per NIBE instructions. Treat as R290 safety function. NIBE lists: Warning appears monthly from 14.5 years until 15 years.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); NIBE-trained heat pump engineer competent with R290 (A3) refrigerant systems.

Certification: Electrical work to BS 7671 by a competent person; Competence for flammable (A3, R290) refrigerant systems; F-gas certification if the refrigerant circuit is opened.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.