241NIBE · NIBE, all models

241 on a NIBE heat pump: Sensor fault AZ3-BT26: Sensor not connected/defective (brine collector in, FLM 3)

Short answer

On a NIBE heat pump, 241 means: Sensor fault AZ3-BT26: Sensor not connected/defective (brine collector in, FLM 3). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Sensor fault AZ3-BT26: Sensor not connected/defective (brine collector in, FLM 3).

Part involved: temperature/pressure sensor.

When it shows: Sensor not connected/defective (brine collector in, FLM 3).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Circulation pump in FLM blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person.

Sources

A code explains what the controller detected, not a confirmed root cause.