Heat pumps · Error codes · NIBE
236NIBE · NIBE, all models

236 on a NIBE heat pump: Sensor fault AZ2-BT20: Sensor not connected/defective (exhaust air, FLM 2)

Short answer

On a NIBE heat pump, 236 means: Sensor fault AZ2-BT20: Sensor not connected/defective (exhaust air, FLM 2). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Sensor fault AZ2-BT20: Sensor not connected/defective (exhaust air, FLM 2).
  • Defrosting fault: 10 failed consecutive defrostings [other NIBE documents: Heat pump (selected outdoor unit) sends fault message to controller].

Part involved: temperature/pressure sensor; evaporator defrost.

When it shows: Sensor not connected/defective (exhaust air, FLM 2) 10 failed consecutive defrostings; Heat pump (selected outdoor unit) sends fault message to controller.

Likely causes:

  • S2125: System temperature and/or flow too low; insufficient available system volume; significant wind effect | F2120: System temperature and/or flow too low; insufficient available system volume; significant wind effect | S2060: System temperature and/or flow too low; insufficient system volume; poor airflow e.g. leaves, snow, ice or strong wind.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Circulation pump in FLM blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the outdoor unit is not blocked by leaves, snow or ice and that nothing obstructs the airflow.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input.
  • Check system volume and flow during defrost, particle filter, circulation pump, evaporator airflow, evaporator/defrost sensors and refrigerant circuit. NIBE lists: System temperature and/or flow too low; insufficient available system volume; significant wind effect; System temperature and/or flow too low; insufficient system volume; poor airflow e.g. leaves, snow, ice or strong wind.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026