Heat pumps · Error codes · NIBE
221NIBE · NIBE, all models

221 on a NIBE heat pump: Low pressure alarm: Heat pump (outdoor unit) sends low pressure fault message to the controller [other NIBE documents: Too low value on low pressure sensor 3 times within 60 min / Low-pressure sensor BP8 (PSL) detects abnormally low pressure]

Short answer

On a NIBE heat pump, 221 means: Low pressure alarm: Heat pump (outdoor unit) sends low pressure fault message to the controller [other NIBE documents: Too low value on low pressure sensor 3 times within 60 min / Low-pressure sensor BP8 (PSL) detects abnormally low pressure]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Low pressure alarm: Heat pump (outdoor unit) sends low pressure fault message to the controller [other NIBE documents: Too low value on low pressure sensor 3 times within 60 min / Low-pressure sensor BP8 (PSL) detects abnormally low pressure].
  • Defrost: The heat pump is defrosting (status alarm) [other NIBE documents: Not an alarm but an operating status / Defrosting in progress].

Part involved: pressure switches/sensors, expansion valve; defrost cycle.

When it shows: Heat pump (outdoor unit) sends low pressure fault message to the controller; Too low value on low pressure sensor 3 times within 60 min; Low-pressure sensor BP8 (PSL) detects abnormally low pressure; Too low value on the low pressure sensor 3 times within 60 minutes The heat pump is defrosting (status alarm); Not an alarm but an operating status; Defrosting in progress.

Likely causes:

  • S2060: Open/short circuit on LP sensor input; defective LP sensor; defective baseboard AA2; open/short circuit or defective suction gas sensor BT17 (Tho-S); lack of refrigerant | F2050: Open/short circuit on LP sensor input; defective LP sensor; defective PWB1; open/short circuit or defective suction gas sensor Tho-S | F2040: Open/short circuit on LP sensor input; defective LP sensor; defective control board; open/short circuit or defective suction gas sensor Tho-S.
  • S2060: Activated when the heat pump runs its defrosting procedure | F2050: Set when the heat pump runs the defrosting procedure.

Is it safe?

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Air source systems: check the outdoor unit is clear of leaves/snow/ice. Read the heating system pressure gauge and note the reading for your installer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. No action needed: this is a normal operating status. Vapour/steam from the outdoor unit during defrost is normal.

What the engineer will check

  • Check heating medium flow, particle filter and circulation pump; check pressure switches/sensors, expansion valve, service valves and refrigerant charge (F-gas qualified). NIBE lists: Open/short circuit on LP sensor input; defective LP sensor; defective control board in outdoor unit; open/short circuit on suction gas sensor (Tho-S) input; Open/short circuit on LP sensor input; defective LP sensor; defective baseboard AA2; open/short circuit or defective suction gas sensor BT17 (Tho-S); lack of refrigerant; Open/short circuit on LP sensor input; defective LP sensor; defective PWB1; open/short circuit or defective suction gas sensor Tho-S; Open/short circuit on LP sensor input; defective LP sensor; defective control board; open/short circuit or defective suction gas sensor Tho-S.
  • None unless defrosts are excessive; then check airflow and evaporator sensor. NIBE lists: Activated when the heat pump runs its defrosting procedure; Set when the heat pump runs the defrosting procedure.

Who to ask for: Heat pump engineer with F-gas qualification (NIBE-trained / NIBE PRO installer); NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: F-gas certification for refrigerant circuit work (plus flammable-refrigerant competence for R290/R32 models); None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026