215 on a NIBE heat pump: Inverter error type III (temporary): Temporary inverter fault type III

Short answer

On a NIBE heat pump, 215 means: Inverter error type III (temporary): Temporary inverter fault type III. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Inverter error type III (temporary): Temporary inverter fault type III.
  • High temperature condenser supply (BT12): Supply temperature BT12 out of the condenser above maximum [other NIBE documents: Too high temperature out from the condenser. Self-resetting].

Part involved: inverter and compressor drive; heating medium flow, charge pump, particle filter.

When it shows: Temporary inverter fault type III Supply temperature BT12 out of the condenser above maximum; Too high temperature out from the condenser. Self-resetting.

Likely causes:

  • S2060: Low flow during heating operation; temperatures set too high | F2050: Low flow during heating operation; too high set temperatures.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Compressor blocked; escalates to permanent inverter alarm.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Read the heating system pressure gauge and check that radiator/underfloor thermostats are not all closed; check heating and hot water temperature settings have not been changed.

What the engineer will check

  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor.
  • Check heating medium flow (pump speed/settings, particle filter, air in system), heating curve and hot water settings, correct sensor placement and flow/return connections. NIBE lists: Low flow during heating operation; temperatures set too high; Low flow during heating operation; too high set temperatures.

Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician; NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales); None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.