207 on a NIBE heat pump: Com. error HW-comfort: No communication with the hot water comfort accessory

Short answer

On a NIBE heat pump, 207 means: Com. error HW-comfort: No communication with the hot water comfort accessory. The manual does not say whether the heat pump stops.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Com. error HW-comfort: No communication with the hot water comfort accessory.
  • Com.flt PCA accessory climate system 6: Communication to accessory card missing; may be due to temporary external disturbance e.g. thunder.

Part involved: PCB / accessory board communication.

When it shows: No communication with the hot water comfort accessory Communication to accessory card missing; may be due to temporary external disturbance e.g. thunder.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning

The manual does not say whether the heat pump stops.

Resetting itself: yes - information messages reset automatically when the cause is rectified.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.