SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · NIBE
181NIBE · NIBE, all models

181 on a NIBE heat pump: Failed periodic increase: Periodic hot water increase did not reach stop temperature within 5 hours [other NIBE documents: Periodic hot water increase did not reach stop temperature in 5 hours]

Short answer

On a NIBE heat pump, 181 means: Failed periodic increase: Periodic hot water increase did not reach stop temperature within 5 hours [other NIBE documents: Periodic hot water increase did not reach stop temperature in 5 hours]. The heat pump keeps running.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Failed periodic increase: Periodic hot water increase did not reach stop temperature within 5 hours [other NIBE documents: Periodic hot water increase did not reach stop temperature in 5 hours].
  • Non-calibrated air flow sensor: Air flow sensor has not been calibrated.

Part involved: heating medium flow, charge pump, particle filter; fans, air filters, air sensors.

When it shows: Periodic hot water increase did not reach stop temperature within 5 hours; Periodic hot water increase did not reach stop temperature in 5 hours Air flow sensor has not been calibrated.

Likely causes:

  • Incorrect settings.

Is it safe?

Does the heat pump stop?No
SeverityInformation only

The heat pump keeps running.

Resetting itself: yes - Only information.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Read the heating system pressure gauge and check that radiator/underfloor thermostats are not all closed; check heating and hot water temperature settings have not been changed.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.

What the engineer will check

  • Check heating medium flow (pump speed/settings, particle filter, air in system), heating curve and hot water settings, correct sensor placement and flow/return connections. NIBE lists: Incorrect settings.
  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026