SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · NIBE
179NIBE · NIBE, all models

179 on a NIBE heat pump: Com. error FLM: Communication with FLM accessory temporarily missing

Short answer

On a NIBE heat pump, 179 means: Com. error FLM: Communication with FLM accessory temporarily missing. The manual does not say whether the heat pump stops.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Com. error FLM: Communication with FLM accessory temporarily missing.
  • High condensation water level: Alarm from level monitor in condensation water container.

Part involved: PCB / accessory board communication; fans, air filters, air sensors.

When it shows: Communication with FLM accessory temporarily missing Alarm from level monitor in condensation water container.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning

The manual does not say whether the heat pump stops.

Resetting itself: yes - information messages reset automatically when the cause is rectified.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.
  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026