Heat pumps · Error codes · NIBE
175NIBE · NIBE, all models

175 on a NIBE heat pump: Start-up of softstart card: The softstart card is starting up (approx. 20 s) [other NIBE documents: Communication fault to accessory board]

Short answer

On a NIBE heat pump, 175 means: Start-up of softstart card: The softstart card is starting up (approx. 20 s) [other NIBE documents: Communication fault to accessory board]. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Start-up of softstart card: The softstart card is starting up (approx. 20 s) [other NIBE documents: Communication fault to accessory board].
  • Low HTF: Outgoing brine below set minimum temperature and alarm selected.

Part involved: PCB / accessory board communication; brine pump, brine sensors, level monitor.

When it shows: The softstart card is starting up (approx. 20 s); Communication fault to accessory board Outgoing brine below set minimum temperature and alarm selected.

Likely causes:

  • Defective communication cables; accessory activated in display but not connected; incorrectly connected communication cable; incorrectly set DIP switch; no electrical supply to accessory board.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Accessory blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted. NIBE lists: Defective communication cables; accessory activated in display but not connected; incorrectly connected communication cable; incorrectly set DIP switch; no electrical supply to accessory board.
  • Check brine circuit: bleeding, brine pump, brine freezing point/concentration, brine sensors and level monitor/pressure switch; look for brine leaks.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026