172 on a NIBE heat pump: Com. error softstart card: Communication with the softstart card temporarily missing

Short answer

On a NIBE heat pump, 172 means: Com. error softstart card: Communication with the softstart card temporarily missing. The manual does not say whether the heat pump stops.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Com. error softstart card: Communication with the softstart card temporarily missing.
  • Incorrect firmware: Serial number and firmware do not match.

Part involved: PCB / accessory board communication; PCB / software configuration.

When it shows: Communication with the softstart card temporarily missing Serial number and firmware do not match.

Is it safe?

Does the heat pump stop?Not stated
SeverityWarning

The manual does not say whether the heat pump stops.

Resetting itself: yes - information messages reset automatically when the cause is rectified.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Note the alarm and contact your installer; no homeowner action beyond resetting.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted.
  • Check serial number/software versions, PCB type and DIP switch settings; update software or replace PCB as required.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026