171 on a NIBE heat pump: Com. error base card: Communication with the base card temporarily missing [other NIBE documents: Temporary communication fault to PCB AA2]

Short answer

On a NIBE heat pump, 171 means: Com. error base card: Communication with the base card temporarily missing [other NIBE documents: Temporary communication fault to PCB AA2]. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Com. error base card: Communication with the base card temporarily missing [other NIBE documents: Temporary communication fault to PCB AA2].
  • Incorrect serial number: Serial number does not exist.

Part involved: PCB / accessory board communication; PCB / software configuration.

When it shows: Communication with the base card temporarily missing; Temporary communication fault to PCB AA2 Serial number does not exist.

Likely causes:

  • Check communication cables and connections.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the breakers for the heat pump, indoor module and any accessories are on at the consumer unit.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Note the alarm and contact your installer; no homeowner action beyond resetting.

What the engineer will check

  • Check communication cables and connectors between PCBs/accessory boards, DIP-switch addressing, power supply to the accessory board, and that accessories activated in the menu are actually fitted. NIBE lists: Check communication cables and connections.
  • Check serial number/software versions, PCB type and DIP switch settings; update software or replace PCB as required.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person; None specific beyond competent heat pump installer; electrical work to BS 7671.