168 on a NIBE heat pump: Level switch: Brine level switch / pressure switch triggered

Short answer

On a NIBE heat pump, 168 means: Level switch: Brine level switch / pressure switch triggered. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

0 sources

What it means

The manual says: Level switch: Brine level switch / pressure switch triggered.

Part involved: brine pump, brine sensors, level monitor.

When it shows: Brine level switch / pressure switch triggered.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor and brine pump blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check brine circuit: bleeding, brine pump, brine freezing point/concentration, brine sensors and level monitor/pressure switch; look for brine leaks.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.