164 on a NIBE heat pump: Low exhaust air temperature: See alarm 64 (exhaust air below 16 C)

Short answer

On a NIBE heat pump, 164 means: Low exhaust air temperature: See alarm 64 (exhaust air below 16 C). The heat pump keeps running.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Low exhaust air temperature: See alarm 64 (exhaust air below 16 C).
  • High pressure alarm: High pressure switch has triggered repeatedly.

Part involved: fans, air filters, air sensors; pressure switches/sensors, expansion valve.

When it shows: See alarm 64 (exhaust air below 16 C) High pressure switch has triggered repeatedly.

Is it safe?

Does the heat pump stop?No
SeverityInformation only

The heat pump keeps running.

Resetting itself: yes - Automatic reset when temperature exceeds 17 C.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Air source systems: check the outdoor unit is clear of leaves/snow/ice. Read the heating system pressure gauge and note the reading for your installer.

What the engineer will check

  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor.
  • Check heating medium flow, particle filter and circulation pump; check pressure switches/sensors, expansion valve, service valves and refrigerant charge (F-gas qualified).

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); Heat pump engineer with F-gas qualification (NIBE-trained / NIBE PRO installer).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671; F-gas certification for refrigerant circuit work (plus flammable-refrigerant competence for R290/R32 models).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026