162 on a NIBE heat pump: High condenser out: Condenser out has reached max permitted temperature [other NIBE documents: BT12 has exceeded 59 C; reset when below 59 C and BT3 dropped 2 K / High condenser out temperature]
Short answer
On a NIBE heat pump, 162 means: High condenser out: Condenser out has reached max permitted temperature [other NIBE documents: BT12 has exceeded 59 C; reset when below 59 C and BT3 dropped 2 K / High condenser out temperature]. The heat pump keeps running with some functions stopped.
Reviewed 23 September 2026 · 1 source
What it means
The manuals for this range word it in different ways:
- High condenser out: Condenser out has reached max permitted temperature [other NIBE documents: BT12 has exceeded 59 C; reset when below 59 C and BT3 dropped 2 K / High condenser out temperature].
- Overheated softstart: Fuses for the soft start card defective.
Part involved: heating medium flow, charge pump, particle filter; inverter and compressor drive.
When it shows: Condenser out has reached max permitted temperature; BT12 has exceeded 59 C; reset when below 59 C and BT3 dropped 2 K; High condenser out temperature; Supply temperature BT12 out of the condenser above maximum; Too high temperature out from the condenser. Self-resetting Fuses for the soft start card defective.
Likely causes:
- F2120: Normal in certain operating conditions; low flow; incorrect settings | S2060: Low flow during heating operation; temperatures set too high | F2050: Low flow during heating operation; too high set temperatures | F2040: Low flow during heating operation; too high set temperatures.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
The heat pump keeps running with some functions stopped.
Resetting itself: yes - Automatic reset; Compressor blocked.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Read the heating system pressure gauge and check that radiator/underfloor thermostats are not all closed; check heating and hot water temperature settings have not been changed.
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check heating medium flow (pump speed/settings, particle filter, air in system), heating curve and hot water settings, correct sensor placement and flow/return connections. NIBE lists: Incorrectly set heating curve; low heating medium flow; undersized heating system; Normal in certain operating conditions; low flow; incorrect settings; Low flow during heating operation; temperatures set too high; Low flow during heating operation; too high set temperatures.
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor.
Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP); NIBE-trained heat pump engineer and/or qualified electrician.
Certification: None specific beyond competent heat pump installer; electrical work to BS 7671; Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- TECHNICAL INFORMATION - ALARM LIST SMO 40 (TIF EN 2042-1, M12658EN) ↗ · TIF EN 2042-1 M12658EN · page 14 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026