Heat pumps · Error codes · NIBE
151NIBE · NIBE, all models

151 on a NIBE heat pump: Sen flt: CL11-BT51 pool temp sensor: Sensor input unreasonable value for longer than 5 s

Short answer

On a NIBE heat pump, 151 means: Sen flt: CL11-BT51 pool temp sensor: Sensor input unreasonable value for longer than 5 s. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Sen flt: CL11-BT51 pool temp sensor: Sensor input unreasonable value for longer than 5 s.
  • Sens flt from heat pump (BP8/BP4): Repeated sensor failures, low-pressure sensor BP8 (PSL) / high-pressure sensor BP4 (PSH) [other NIBE documents: Sensor fault, low pressure transmitter in F2050 / Alarm generated by the heat pump: low pressure sensor fault].

Part involved: temperature/pressure sensor.

When it shows: Sensor input unreasonable value for longer than 5 s Repeated sensor failures, low-pressure sensor BP8 (PSL) / high-pressure sensor BP4 (PSH); Sensor fault, low pressure transmitter in F2050; Alarm generated by the heat pump: low pressure sensor fault.

Likely causes:

  • Sensor not connected; open-circuit or defective sensor.
  • S2060: Open/short circuit on sensor input; defective baseboard AA2; fault in refrigerant circuit | F2050: Open/short circuit on sensor input; defective control board PWB1; fault in refrigerant circuit.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Pool pump stops.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input. NIBE lists: Sensor not connected; open-circuit or defective sensor.
  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input. NIBE lists: Open/short circuit on sensor input; defective baseboard AA2; fault in refrigerant circuit; Open/short circuit on sensor input; defective control board PWB1; fault in refrigerant circuit.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: Electrical work to BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026