146NIBE · NIBE, all models

146 on a NIBE heat pump: ERS accessory blocked by lev. monitor (listed as range 146-149): Level monitor for ERS 1-4 has tripped (input closed)

Short answer

On a NIBE heat pump, 146 means: ERS accessory blocked by lev. monitor (listed as range 146-149): Level monitor for ERS 1-4 has tripped (input closed). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • ERS accessory blocked by lev. monitor (listed as range 146-149): Level monitor for ERS 1-4 has tripped (input closed).
  • Sensor fault EQ1-BT75: Sensor not connected/defective (cooling flow heat pump).

Part involved: fans, air filters, air sensors; temperature/pressure sensor.

When it shows: Level monitor for ERS 1-4 has tripped (input closed) Sensor not connected/defective (cooling flow heat pump).

Likely causes:

  • Check the level monitor.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Accessory blocked; automatic reset when input open.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.
  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor. NIBE lists: Check the level monitor.
  • Check sensor and its connections/wiring against the wiring diagram; measure sensor resistance against the NIBE temperature/resistance table; check the relevant PCB input.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671; Electrical work to BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026