ALARM-DHWKronoterm · TERMOTRONIC-controlled heat pumps (legacy WP / WPL / WPLV water-water, brine-water, air-water)

ALARM-DHW on a Kronoterm TERMOTRONIC-controlled heat pumps: Device unable to heat DHW above the minimum set value 3 times

Short answer

On a Kronoterm heat pump, ALARM-DHW means: Device unable to heat DHW above the minimum set value 3 times. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Device unable to heat DHW above the minimum set value 3 times.

Part involved: DHW heating.

Likely causes:

  • Insufficient water flow through condenser.
  • DHW sensor not in its correct place.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Manual reset: After fixing the cause restart by holding ENTER for 3 s.

What you can check

  • Note the exact message shown on the TERMOTRONIC display.
  • Check the heating system pressure gauge reading.

What the engineer will check

  • Check pump/valves/strainer, refill/vent; check DHW sensor position.

Who to ask for: heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.