HP on a Kensa heat pump: Overheat warning - no or low flow around heating distribution circuit
Short answer
On a Kensa heat pump, HP means: Overheat warning - no or low flow around heating distribution circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 7 sources
What it means
The manual says: Overheat warning - no or low flow around heating distribution circuit.
Part involved: Load pump / distribution flow.
When it shows: Legacy panel controller: 'Display flashes fault code HP'.
Likely causes:
- Air in water pump, stuck pump impeller, heating valves/actuators closed; can show briefly when switching from DHW to space heating.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: unknown.
Manual reset: unknown.
What you can check
- Note the code shown on the controller/LED; check the heat pump isolator and consumer-unit breaker are on; check thermostat/timer settings.
What the engineer will check
- Bleed load pump via Schrader valve, check pump runs/spin impeller, open distribution valves/actuators.
Who to ask for: Heating engineer / GSHP installer.
Certification: MCS-certified GSHP installer recommended.
What you might notice
Sources
- Single Compressor Compact Heat Pump Manual ↗ · Version 11 · page 41 · Reviewed 23 September 2026
- Twin Compressor Compact Heat Pump Manual ↗ · Version 14 · page 38 · Reviewed 23 September 2026
- High Temperature Single Compressor Compact Heat Pump Manual ↗ · Version 5 · page 41 · Reviewed 23 September 2026
- High Temperature Plant Room Heat Pump Manual ↗ · v4.1 · page 30 · Reviewed 23 September 2026
- Hybrid Twin Compressor Compact Heat Pump Manual ↗ · Version 4 · page 38 · Reviewed 23 September 2026
- Plant Room Heat Pump Manual ↗ · Version 11.1 · page 30 · Reviewed 23 September 2026
- Shoebox Heat Pump Installation and Commissioning Manual (ground array) ↗ · Version 4 · page 33 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.