78 on a Hitachi heat pump: RF communication failure (intelligent thermostat accessory)

Short answer

On a Hitachi heat pump, 78 means: RF communication failure (intelligent thermostat accessory). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: RF communication failure (intelligent thermostat accessory).

Part involved: RF bridge.

Likely causes:

  • No communication for 1 hour with one or two RF receivers bound to the RF-Bridge.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

No need to switch off — call an engineer if it comes back.

Resetting itself: no.

Manual reset: Stop the unit (via unit controller / power off-on) after the cause is fixed.

What you can check

  • Read and note the alarm code and any retry code (e.g. P70) shown on the unit controller.
  • Check the heat pump supply breaker/isolator at the consumer unit is ON.
  • Restart once via the unit controller (or switch off/on at the isolator) - the manual states the unit must be stopped to release most alarms; if the code returns, call an engineer.
  • Check the room thermostat/controller display is powered and settings/timer are as expected.

What the engineer will check

  • Follow SMGB0146 section 6.7 troubleshooting flowchart for alarm 78.
  • Check H-Link / transmission wiring polarity, continuity and terminal tightness.
  • Check PCB fuses and DIP-switch/address settings.
  • Check power to the other unit (outdoor/indoor/controller).

Who to ask for: Heat pump installer / service engineer (controls wiring).

Certification: None specific.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026