SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Hitachi
72Hitachi

72 on a Hitachi heat pump: Thermostat heater alarm - high temperature detected in the electric heater

Short answer

On a Hitachi heat pump, 72 means: Thermostat heater alarm - high temperature detected in the electric heater. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Thermostat heater alarm - high temperature detected in the electric heater.

Part involved: electric heater thermostat.

When it shows: Temperature inside the electric heater exceeds the safety temperature (heater thermostat THe opens).

Likely causes:

  • Heater safety thermostat (THe) opened; wiring of single-phase bridge on TB1; blown heater fuses.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Stop the unit (via unit controller / power off-on) after the cause is fixed.

What you can check

  • Read and note the alarm code and any retry code (e.g. P70) shown on the unit controller.
  • Check the heat pump supply breaker/isolator at the consumer unit is ON.
  • Restart once via the unit controller (or switch off/on at the isolator) - the manual states the unit must be stopped to release most alarms; if the code returns, call an engineer.
  • Check the system pressure gauge on the indoor unit (Yutaki S / S Combi have a factory manometer; Yutaki M uses a field-fitted gauge) - Hitachi gives about 1.5-2.0 bar as normal and it must stay above 1 bar and below 3 bar.
  • Check the filling loop is closed.

What the engineer will check

  • Follow SMGB0146 section 6.7 troubleshooting flowchart for alarm 72.
  • Check water pump operation and fuse, pump feedback.
  • Check all circuit valves open, clean strainers/filters (Filter+ valve).
  • Check water pressure > 1 bar, bleed air, check flow and pressure switch/sensor continuity.
  • Check heater contactors, water thermistors and minimum system water volume.

Who to ask for: Heating engineer / MCS heat pump installer.

Certification: G3 unvented qualification where a DHW cylinder is involved.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026