E211 on a CTC control system alarm/information platform: Risk of freezing low flow (critical): flow < 10 l/min (610M/614M/708M/712M) or < 15 l/min (622M/720M) for >30 s during defrost; EcoAir 600M/700M/C100 with flow sensor
Short answer
On a CTC heat pump, E211 means: Risk of freezing low flow (critical): flow < 10 l/min (610M/614M/708M/712M) or < 15 l/min (622M/720M) for >30 s during defrost; EcoAir 600M/700M/C100 with flow sensor. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Risk of freezing low flow (critical): flow < 10 l/min (610M/614M/708M/712M) or < 15 l/min (622M/720M) for >30 s during defrost; EcoAir 600M/700M/C100 with flow sensor.
Part involved: heating circuit flow / flow sensor.
Likely causes:
- Heating circuit temperature and/or flow rate too low.
- Faulty HP in/HP out sensors (E135/E216).
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Manual reset: Critical alarms [E135]/[E211]/[E216]/[E217] can be acknowledged three times with code 4005 (Installer/Service/Coded settings); after the fourth the heat pump is blocked; counters reset after one year without alarms.
What you can check
- Note the alarm code/text, the product model and serial number and contact your installer.
- Check radiator/UFH valves in the house are not all closed.
- Check system pressure gauge reading is in the normal range.
What the engineer will check
- Check circulation pump speed, dirt filter, pipe sizes and flow sensor.
- Ensure heating return at least 25 C during defrost; consider volume tank.
- Check HP in/out sensors with an external thermometer and replace if required.
Who to ask for: heat pump / hydraulic.