Heat pumps · Error codes · Cool Energy
P3Cool Energy · EcoStore all-in-one exhaust-air DHW heat pump

P3 on a Cool Energy EcoStore all-in-one exhaust-air DHW heat pump: Compressor abnormally stopped protection

Short answer

On a Cool Energy heat pump, P3 means: Compressor abnormally stopped protection. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor abnormally stopped protection.

Likely causes:

  • Discharge temperature not sufficiently above evaporator temperature after running - compressor broken or bad PCB-compressor connection.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heat pump's breaker/isolator at the consumer unit is switched on (do not repeatedly reset if it trips).

What the engineer will check

  • Check compressor windings and wiring/phase sequence.
  • Check inverter drive parameters match compressor model.
  • Check operating envelope (flow, pressures, load).

Who to ask for: refrigeration / F-gas heat pump engineer.

Certification: F-gas certification; electrical competence.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026