AL137 on a Cool Energy inverTech: Flow switch alarm

Short answer

On a Cool Energy heat pump, AL137 means: Flow switch alarm. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow switch alarm.

When it shows: Low flow detected by flow switch on the return pipe.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Clears when water flow is restored (manual p.33).

What you can check

  • Read and note the code shown on the controller display, then contact your installer or service engineer.
  • Check the heating system pressure gauge reading against the value in your handover documents (manufacturer commissioning values: typically 1-2 bar) and that the filling loop is closed.

What the engineer will check

  • Check water flow rate/flow switch and wiring.
  • Check strainer/magnetic filter for blockage.
  • Vent air from the system.
  • Check circulating pump operation and pipe sizing.
  • Check valves/zone valves are open.

Who to ask for: heating / plumbing heat pump installer.

Certification: None specific (unvented/G3 if cylinder work).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026