FiL on a Climer Technology S.L.L Climer ECOHEAT heat pump water heater: Compressor maintenance alarm

Short answer

On a Climer Technology S.L.L heat pump, FiL means: Compressor maintenance alarm. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Compressor maintenance alarm.

Part involved: compressor inverter drive board.

Likely causes:

  • By touching any key, you delete the compressor functioning hours.

Is it safe?

Does the heat pump stop?No
SeverityInformation only
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: unknown.

What you can check

  • This is a maintenance reminder; the manual says touching any key clears the compressor hours counter. Arrange routine servicing (including air filter/evaporator cleaning) with your installer.

What the engineer will check

  • Check supply voltage and phase at the unit terminals.
  • Check compressor U/V/W connections and compressor winding resistance.
  • Check drive board heatsink cooling and fan.
  • Replace the inverter/driver board if faults persist.

Who to ask for: Heat pump engineer.

Certification: Heat pump installer competence; F-gas and flammable-refrigerant (R32/R290) handling competence for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026