What do Growatt SPH battery errors 500, 502 and 506 mean?

Short answer

On a Growatt SPH hybrid, Error 500 means the inverter has lost communication with the lithium battery's BMS. Error 502 means battery voltage is below 42 V, and Error 506 means the battery circuit is open. Check the battery is on; low-voltage errors often clear after recharging. Persistent codes need the installer to check the battery cables and communications.

Last checked 24 September 2026 · 1 source

What does this mean?

Error 505 battery reversed; 503 battery voltage >60 V. EPS overload (607) three times locks backup for one hour.

What should I do first?

Record the code and current battery state before changing settings. Follow only the owner-safe reset steps in the manual.

When do I need an engineer?

Use an installer or manufacturer support route if the fault returns, involves isolation or protection, or the manual does not give an owner reset.

What to do next

If the system is hot, smoking, damaged or making unusual electrical noises, move away from it and follow the manufacturer emergency guidance.